Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
Environ Sci Pollut Res Int ; 28(29): 39322-39332, 2021 Aug.
Article in English | MEDLINE | ID: covidwho-1549509

ABSTRACT

The objective of this study is to understand the effect of indoor air stability on personal exposure to infectious contaminant in the breathing zone. Numerical simulations are carried out in a test chamber with a source of infectious contaminant and a manikin (Manikin A). To give a good visual illustration of the breathing zone, the contaminant source is visualized by the mouth of another manikin. Manikin A is regarded as a vulnerable individual to infectious contaminant. Exposure index and exposure intensity are used as indicators of the exposure level in the breathing zone. The results show that in the stable condition, the infectious contaminant proceeds straightly towards the breathing zone of the vulnerable individual, leading to a relatively high exposure level. In the unstable condition, the indoor air experiences a strong mixing due to the heat exchange between the hot bottom air and the cool top air, so the infectious contaminant disperses effectively from the breathing zone. The unstable air can greatly reduce personal exposure to the infectious contaminant in the breathing zone. This study demonstrates the importance of indoor air stability on personal exposure in the indoor environment and provides a new direction for future study of personal exposure reduction in the indoor environment.


Subject(s)
Air Pollution, Indoor , Ventilation , Air Movements , Air Pollution, Indoor/analysis , Manikins
2.
J Environ Sci (China) ; 108: 175-187, 2021 Oct.
Article in English | MEDLINE | ID: covidwho-1046319

ABSTRACT

The Coronavirus Disease 2019 (COVID-19) highlights the importance of understanding and controlling the spread of the coronavirus between persons. We experimentally and numerically investigated an advanced engineering and environmental method on controlling the transmission of airborne SARS-CoV-2-laden aerosols in the breathing microenvironment between two persons during interactive breathing process by combining the limited space air stability and a ventilation method. Experiments were carried out in a full-scale ventilated room with different limited space air stability conditions, i.e., stable condition, neutral condition and unstable condition. Two real humans were involved to conducted normal breathing process in the room and the exhaled carbon dioxide was used as the surrogate of infectious airborne SARS-CoV-2-laden aerosols from respiratory activities. A correspondent numerical model was established to visualize the temperature field and contaminated field in the test room. Results show that the performance of a ventilation system on removing infectious airborne SARS-CoV-2-laden aerosols from the interpersonal breathing microenvironment is dependent on the limited space air stability conditions. Appropriate ventilation method should be implemented based on an evaluation of the air condition. It is recommended that total volume ventilation methods are suitable for unstable and neutral conditions and local ventilation methods are preferable for stable conditions. This study provides an insight into the transmission of airborne SARS-CoV-2-laden aerosols between persons in ventilated rooms with different limited space air stability conditions. Useful guidance has been provided to cope with COVID-19 in limited spaces.


Subject(s)
COVID-19 , SARS-CoV-2 , Aerosols , Humans
SELECTION OF CITATIONS
SEARCH DETAIL